Skip to main content

Document library

PUBLICATION · Technical Report

Example Implementation for Cascading Leaks in Large-Scale Hydrogen Storage Risk Assessments

Leaks in a hydrogen system can have destructive effects on other components within the system, leading to cascading leaks. The risk of cascading leaks is not currently quantified in many existing risk frameworks, but the prevalence of cascading failures in historical hydrogen facility accidents necessitates further study. A method for quantifying the probability, frequency, and risk of cascaded leaks is proposed.

PUBLICATION · Technical Report

Evaluation of Hydrogen Storage Quantity Limits for Safety Requirements

As hydrogen storage facilities increase in size and capacity, it may be necessary to evaluate codes and standards that regulate hydrogen, especially in relation to allowable aggregate quantities. Existing regulations for other substances with comparable hazards such as oxygen, natural gas, and petroleum were reviewed; most fuels do not have aggregate quantity limits despite sometimes having individual tank capacity restrictions or limits for certain non-industrial, indoor, or small-scale applications. This precedent suggests that specifying a hydrogen quantity limit may not be necessary.

PUBLICATION · Technical Report

Quantitative Risk Assessment for Hydrogen-Powered Locomotive Refueling

Hydrogen powered locomotives are being explored to reduce emissions in rail applications. The risks of operations like refueling should be understood to ensure safe environments for workers and members of the public. Sensitivity analyses were conducted using HyRAM+ to identify major drivers of risk and compare effects of system parameters on individual risk. The consequences of jet fires from full-bore leaks dominated the risk, compared to explosions or smaller leaks.

PUBLICATION · Technical Report

Quantitative risk assessment examples for underground hydrogen storage facilities

Hydrogen energy storage can be used to achieve goals of national energy security, renewable energy integration, and grid resilience. Adapting underground natural gas storage facility (UNGSF) infrastructure for underground hydrogen storage (UHS) is one method of storing large quantities of hydrogen that has already largely been proven to work for natural gas.

PUBLICATION · Technical Report

Updated Filter Leak Frequencies for Use in Risk Assessments

Quantitative risk assessment (QRA) is highly dependent on data, leading to more robust models as new and updated data is acquired. The Hydrogen Plus Other Alternative Fuels Risk Assessment (HyRAM+) QRA capabilities include calculations of individual risk from leaks in a gaseous hydrogen facility due to the potential effects of jet fires and explosions. Leak frequencies are acquired through statistical analysis of published data from a variety of sources and industries.

Keywords:

PUBLICATION · Technical Report

Regulations, Codes, and Standards Review for Underground Hydrogen Storage

Hydrogen continues to show promise as a viable contributor to achieving energy storage goals such as energy security and decarbonization in the United States. However, many new and expanded hydrogen use applications will require identifying methods of larger-scale storage than the solutions that currently exist for smaller storage applications. One possibility is to store large quantities of gaseous hydrogen below ground level.

PUBLICATION · Technical Report

Hydrogen Plus Other Alternative Fuels Risk Assessment Models (HyRAM+) Version 5.1 Technical Reference Manual

The HyRAM+ software toolkit provides a basis for conducting quantitative risk assessment and consequence modeling for hydrogen, natural gas, and autogas systems. HyRAM+ is designed to facilitate the use of state-of-the-art models to conduct robust, repeatable assessments of safety, hazards, and risk. HyRAM+ integrates deterministic and probabilistic models for quantifying leak sizes and rates, predicting physical effects, characterizing hazards (thermal effects from jet fires, overpressure effects from delayed ignition), and assessing impacts on people.

PUBLICATION · Technical Report

Safety of Mobile Hydrogen and Fuel Cell Technology Applications: An Investigation by the Hydrogen Safety Panel

Safe practices in the production, storage, distribution, and use of hydrogen are essential for the widespread acceptance of hydrogen and fuel cell technologies. A catastrophic failure in any hydrogen project could damage public perception of hydrogen and fuel cells. Given the nascent nature of the mobile hydrogen applications, incidents involving mobile equipment can have detrimental impacts for the public as well as stakeholders and project proponents who are committed to hydrogen’s use as a safe alternative energy resource. 

Disclaimer- The documents and references herein are for information purposes only and should not be construed as endorsement by the Hydrogen Safety Panel.