Skip to main content

Document library

PUBLICATION · Technical Report

Hydrogen Plus Other Alternative Fuels Risk Assessment Models (HyRAM+) Version 5.1 Technical Reference Manual

The HyRAM+ software toolkit provides a basis for conducting quantitative risk assessment and consequence modeling for hydrogen, natural gas, and autogas systems. HyRAM+ is designed to facilitate the use of state-of-the-art models to conduct robust, repeatable assessments of safety, hazards, and risk. HyRAM+ integrates deterministic and probabilistic models for quantifying leak sizes and rates, predicting physical effects, characterizing hazards (thermal effects from jet fires, overpressure effects from delayed ignition), and assessing impacts on people.

PUBLICATION · Technical Report

Safety of Mobile Hydrogen and Fuel Cell Technology Applications: An Investigation by the Hydrogen Safety Panel

Safe practices in the production, storage, distribution, and use of hydrogen are essential for the widespread acceptance of hydrogen and fuel cell technologies. A catastrophic failure in any hydrogen project could damage public perception of hydrogen and fuel cells. Given the nascent nature of the mobile hydrogen applications, incidents involving mobile equipment can have detrimental impacts for the public as well as stakeholders and project proponents who are committed to hydrogen’s use as a safe alternative energy resource. 

PUBLICATION · Technical Report

LPG Component Leak Frequency Estimation

Liquefied petroleum gas (LPG) is used in heating, cooking, and as a vehicle fuel (called autogas). A safety risk assessment may be needed to assess potential hazard scenarios and inform the regulations, codes, and standards that apply to LPG facilities, such as autogas refueling facilities. The frequency of unintended releases in an LPG system is an important aspect of a system quantitative risk assessment. This report documents estimation of leakage frequencies for individual components of LPG systems.

PUBLICATION · Technical Report

Hydrogen-Ready Appliances Assessment Report

State policy targets on greenhouse gas emission reductions and other decarbonization initiatives are creating a movement toward low or zero-carbon gases and fuels. Given its versatility as an energy carrier and its potential for use in a broad range of applications, hydrogen is gaining in popularity, and natural gas providers are looking at integrating it into their networks.

PUBLICATION · Technical Report

Technical Justifications for Liquid Hydrogen Exposure Distances

The previous separation distances in the National Fire Protection Association (NFPA) Hydrogen Technologies Code (NFPA 2, 2020 Edition) for bulk liquid hydrogen systems lack a well-documented basis and can be onerous. This report describes the technical justifications for revisions of the bulk liquid hydrogen storage setback distances in NFPA 2, 2023 Edition. Distances are calculated based on a leak area that is 5% of the nominal pipe flow area.

PUBLICATION · Technical Report

Hydrogen Plus Other Alternative Fuels Risk Assessment Models (HyRAM+) Version 5.0 Technical Reference Manual

The HyRAM+ software toolkit provides a basis for conducting quantitative risk assessment and consequence modeling for hydrogen, natural gas, and autogas systems. HyRAM+ is designed to facilitate the use of state-of-the-art models to conduct robust, repeatable assessments of safety, hazards, and risk. HyRAM+ integrates deterministic and probabilistic models for quantifying leak sizes and rates, predicting physical effects, characterizing hazards (thermal effects from jet fires, overpressure effects from delayed ignition), and assessing impacts on people.

PUBLICATION · Technical Report

Compressed Natural Gas Component Leak Frequency Estimation

The frequency of unintended releases in a compressed natural gas system is an important aspect of the system quantitative risk assessment. The frequencies for possible release scenarios, along with engineering models, are utilized to quantify the risks for compressed natural gas facilities. This report documents component leakage frequencies representative of compressed natural gas components that were estimated as a function of the normalized leak size.

Keywords:

PUBLICATION · Technical Report

Liquid Hydrogen Heavy-Duty Vehicle Safety Review and Refueling Facility Design

Liquid hydrogen (LH2) used as a fuel onboard a heavy-duty vehicle can result in increased storage capacity and faster refueling relative to compressed gas. However, there are concerns about hydrogen losses from boil-off, potential safety issues, gaps in codes and standards for cryogenic hydrogen fuel, and technical challenges with LH2 systems for widespread transportation applications.

PUBLICATION · Technical Report

Hydrogen Incident Recovery Guide

This document applies to the recovery phase of a typical emergency management framework that includes planning, response, mitigation, and recovery. This document provides practical guidance with a checklist to help an organization recover from a hydrogen incident and return to normal operations after the event scene has been stabilized and returned to the organization by the incident commander. This document does not include activities related to the immediate emergency response and initial investigations performed by other entities.

Disclaimer- The documents and references herein are for information purposes only and should not be construed as endorsement by the Hydrogen Safety Panel.