Reduced-Order Modeling of Hydrogen Releases from Vent Stacks and with Wind Effects

The physical release behavior of hydrogen is important to understand from a safety and design perspective. The consequences of unignited pressurized gaseous hydrogen plumes exiting vent stacks were considered by extending and modifying existing general hydrogen plume models. Entrainment, vent stack backpressure, and the flow regime of hydrogen exiting the vent were found to be significant factors affecting plume shape and size, but further investigation and validation with unchoked, low-Froude-number flows is recommended to improve the model’s robustness.

PUBLICATION · Technical Report

Assessment of Vibration and Shock Loading Environments on Steels Used in Railroad Applications Considering Hydrogen Embrittlement

Studies that examine the combined effects of hydrogen and rail loading environments in the context of hydrogen embrittlement of steels have not been performed. Large-scale hydrogen storage requires either gaseous hydrogen stored in pressure vessels and tubing or liquid hydrogen in cryogenic, insulated tanks. Since the focus of this study is on steels, we examine the influence of hydrogen on stainless steel used for high pressure tubing and cryogenic tanks and Cr-Mo steel liners used in gaseous pressure vessels.

PUBLICATION · Technical Report

Prioritizing Uncertainties in Hydrogen Contribution to Risk in Post-Crash Outcomes for Rail

This report presents analysis from Sandia National Laboratories predicting contributions to risk associated with the use of hydrogen technology for rail. Event sequence diagrams are used to describe possible accident scenarios and progressions. Initiating event frequencies and branch event probabilities for each scenario are quantified with uncertainty using distributions fit to Federal Railroad Administration and U.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration data on applicable accidents from 2000 to 2020.

PUBLICATION · Technical Report

Audible Noise Modeling of Hydrogen Release Sonic Hazards in Rail Maintenance Facilities

This study implemented validated literature models to predict audible noise due to pressurized gaseous hydrogen releases through a thermally-activated pressure relief device (TPRD) and attached vent stack. A literature survey discovered limited hydrogen-specific noise prediction models validated by experiments. However, empirical noise prediction models for air flowing through pipes and valves were identified.

PUBLICATION · Technical Report

Technical Justifications for Outdoor Bulk Gaseous Hydrogen Storage Setback Distances

Setback distances define a prescribed distance between a potentially hazardous system and different types of other systems, people, buildings, or materials that may be exposed to that hazard. Riskinformed separation distances are not meant to completely eliminate risk, but rather to limit the risk to an acceptable level. A sensitivity study of risk suggested that a leak size of 3% of the pipe cross-sectional area would be a conservative but reasonable basis.

PUBLICATION · Technical Report

Human Factors Considerations for Hydrogen Rail Refueling and Maintenance

The Federal Railroad Administration (FRA) contracted Sandia National Laboratories to review the risks introduced specifically through human interactions within hydrogen rail refueling and maintenance activities and present recommendations for future system development and implementation. Due to the lack of domestic hydrogen-powered trains at the time of review, observational data was collected on analogous existing systems to consider various ways hydrogen might be implemented within future designs.

PUBLICATION · Technical Report

Example Safety Plan for Hydrogen and Fuel Cell Projects

This document provides an example safety plan in Attachment A associated with hydrogen and fuel cells, where there is a significant flammability or explosive hazard from quantities, pressures, exposures, or other conditions. Hydrogen is unique among flammable gases in that small quantities may result in ignition or explosions. This example safety plan was developed by Pacific Northwest National Laboratories (PNNL) and its Hydrogen Safety Panel (HSP) members to assist entities working with hydrogen to ensure the protection of life, property, and the environment.

PUBLICATION · Technical Report

Hydrogen Risk Assessment Models (HyRAM) (Version 3.0 Technical Reference Manual)

The HyRAM software toolkit provides a basis for conducting quantitative risk assessment and consequence modeling for hydrogen infrastructure and transportation systems. HyRAM is designed to facilitate the use of state-of-the-art science and engineering models to conduct robust, repeatable assessments of hydrogen safety, hazards, and risk. HyRAM includes generic probabilities for hydrogen equipment failures, probabilistic models for the impact of heat flux on humans and structures, and computationally and experimentally validated first-order models of hydrogen release and flame physics.

PUBLICATION · Technical Report

Hydrogen Incident Examples: Select Summaries of Hydrogen Incidents from the H2tools.org Lessons Learned Database

The Hydrogen Safety Panel was established by the U.S. Department of Energy (DOE) to provide independent safety reviews and guidance to contractors in the DOE Hydrogen and Fuel Cells Program. In September 2017, the panel set up a task group to compile select hydrogen incidents from the H2Tools.org Lessons Learned database (https://h2tools.org/lessons) in a publication form for written reference, that are most pertinent to various types of DOE contractor projects. This report is the result of the task group’s work. 

PUBLICATION · Technical Report

Evaluation of Risk Acceptance Criteria for Transporting Hazardous Materials

This report reviews and offers recommendations from Sandia National transportation of hazardous materials in the U.S. The risk criteria should be used with the results of a quantitative risk assessment (QRA) in risk acceptance decision-making. The QRA for transportation is fundamentally the same as a fixed facility. However, there are differences in calculations of both the probabilities of occurrence and location of hazards.