Skip to main content

Fire tests carried out in FCH JU Firecomp project, recommendations and application to safety of gas storage systems

Abstract

In the event of a fire, composite pressure vessels behave very differently from metallic ones: the material is degraded, potentially leading to a burst without significant pressure increase. Hence, such objects are, when necessary, protected from fire by using thermally activated devices (TPRD), and standards require testing cylinder and TPRD together. The pre-normative research project FireComp aimed at understanding better the conditions which may lead to burst, through testing and simulation, and proposed an alternative way of assessing the fire performance of composite cylinders. This approach is currently used by Air Liquide for the safety of composite bundles carrying large amounts of hydrogen gas. (C) 2018 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.

Year of Publication
2019
Journal
International Journal of Hydrogen Energy
Volume
44
Issue
17
Number of Pages
9100-9109+
Date Published
Apr 2
Type of Article
Article; Proceedings Paper
ISBN Number
0360-3199
Accession Number
WOS:000463689300041
DOI
10.1016/j.ijhydene.2018.04.070
Short Title
Fire tests carried out in FCH JU Firecomp project, recommendations and application to safety of gas storage systems
Alternate Journal
Int J Hydrogen Energ