Skip to main content

A simple approach to voltage breakdown analysis for proton exchange membrane water electrolysis

A simple approach to voltage breakdown analysis for proton exchange membrane water electrolysis

Author(s)
S. Fortiner
H. Soucie
R. Gawas
A. Kusoglu
R. Mukundan
K. Ayers
Keywords
Proton Exchange Membrane (PEM)
Electrolysis
Voltage
High-Frequency Resistance - HFR
Electrochemical Impedance Spectroscopy - EIS
Abstract

Proton exchange membrane (PEM) electrolysis for hydrogen production is a rapidly growing industry. Many universities, laboratories, and companies are devoting time and resources to develop materials to allow construction of more efficient electrolyzer stacks. New materials can include membranes, porous transport media, and catalysts, all of which have unique impacts on electrolyzer cell performance. To isolate the impact of a new material and properly evaluate its performance, it is essential to understand the key voltage losses in a cell that add up to the measured cell voltage. This basic protocol outlines the assessment of thermodynamic, kinetic, ohmic, and residual contributions to the voltage losses in a PEM electrolyzer cell. Establishing a standardized protocol ensures consistency among various experiments for material-performance evaluations and aids collaboration between research institutions.

AWST Technology
Low Temperature Electrolysis (LTE)
Protocol #
LTE-NA
Validation Results
Comments
You must request access and log in to submit a comment. Login