A simple approach to voltage breakdown analysis for proton exchange membrane water electrolysis
Proton exchange membrane (PEM) electrolysis for hydrogen production is a rapidly growing industry. Many universities, laboratories, and companies are devoting time and resources to develop materials to allow construction of more efficient electrolyzer stacks. New materials can include membranes, porous transport media, and catalysts, all of which have unique impacts on electrolyzer cell performance. To isolate the impact of a new material and properly evaluate its performance, it is essential to understand the key voltage losses in a cell that add up to the measured cell voltage. This basic protocol outlines the assessment of thermodynamic, kinetic, ohmic, and residual contributions to the voltage losses in a PEM electrolyzer cell. Establishing a standardized protocol ensures consistency among various experiments for material-performance evaluations and aids collaboration between research institutions.